Doc inlet temp during regen

During an active regen, engine exhaust temp is slightly higher than normal but not significantly. Maybe 50 to 100 deg. F at best. The high temps are in the exhaust NOX/DPF filter. Everything upstream of that is pretty much normal from my observations. See this video on an entire active regeneration.

The calibration results of (a) DPF outlet temperature and (b) DPF pressure drop during active regeneration. DPF regeneration conditions: DPF SV = 20,000 h-1 , DPF soot loading = 4 g/L, DPF inlet ...13) Monitor DOC inlet temperature. It MUST be greater than 400°C (750°F). If it is not above 400°C (750°F), block off part of the radiator with cardboard. Be careful that coolant temperatures do not go high enough to cause a Check Engine light. 14) Continue to monitor the DOC inlet temperature to make sure it is greater than 400°C (750°F).Had a forced Regen done and off I went. 150 miles later the same code came back again. so I ignored it for another 250 miles and then second alert saying Air Intake system problem. Had a second Regen done and noticed Inlet manifold pressure was very high but as the regen was going on this issue reduced to normal levels.

Did you know?

EGT stands for Exhaust Gas Temperature. The EGT sensor is responsible for reading the temperatures of the aftertreatment system components such as inlet DOC, ...No fault codes, regen starts both fuel pressure s around 60 psi and temperature at doc raise normal above 600° the fuel dosing starts and dpf temperatures inlet and outlet raise until 750- to almost 800.High DOC outlet temperature for DPF regeneration during the FTP cycle CAT 3126 engine. As seen in the chart, maintaining constant DOC outlet temperature at variable exhaust gas mass flow rate and variable DOC inlet temperature conditions is not a trivial task. During a parked regen on a DD15, the SCR Inlet NOx sensor should be around 200-300ppm. DD13 SCR Inlet NOx sensor is slightly higher around 400-500ppm. The SCR Outlet NOx should be somewhere in the neighborhood of 5-25ppm for all DD Platforms. The other true method in testing the NOx sensors is to perform a regular parked regen, then perform ...

Catalyst (DOC), a chemical reaction occurs, and the exhaust system temperature increases to a level that oxidizes the soot in the filter. W2005917 Aftertreatment Fuel Injector (AFI) The Discharge Recirculation Valve (DRV), mounted on the charge air cooler inlet pipe, increases exhaust system temperature by recirculating air back into the ...Throttle Valve Actual NOT USED DURING A PARKED REGEN Fuel Comp Pressure 85 - 92 psi ... DOC Inlet Temp 700 - 950 ° F DOC Outlet Temp 1050 - 1150° F DPF Inlet Pressure 0.5 psi - 1.0 psi DPF Outlet Pressure 0.01 psi to 0.9 psi Doser Injection Status gradual increase from 5% to 45% • DOC inlet temp must be at 525° F or higher toGood morning Roy, I replace the SCR Outlet Temp Sensor yesterday ran a regen and it went on forever, had to sop it after one hour. The Temps slowly build up, these are the readings after about 1 hour DOC inlet-747 DOC Oultet 1010 DPF Outlet 1092 SCR inlet 1028 SCR Outlet 1045 What do yuo recommend next Still showing same codes SCR NOX ...The inlet temperature was 200°C and the detector temperature was 220°C. Nitrogen was used as the carrier gas. There was a flow rate of 2 mL/min, no split injection, and an injection volume of 1 μL. The column was a DB-WAX-etr polar column (30.0 m×0.53 mm×1.00 μm).The temperature was kept constant as was the pressure at 4.40 psi.The furnace temperature heating program included: first held ...

Hi Mike. No fault codes, regen starts both fuel pressure s around 60 psi and temperature at doc raise normal above 600° the fuel dosing starts and dpf temperatures inlet and outlet raise until 750- to … read moreWhat are the temps showing when you are running the regen? Presuming you are using DDDL? You should see the dpf inlet, the catalyst, the outlet. You want the inlet to show 400, the filter inlet at 450 and above, and the outlet at 450 and above for when the doser will open up and start heating the catalyst up more.Soot load was level 5. performed a parked regen. DOC inlet temp was bias. ... Mack MP8 regen issues. IROC Location Offline Posting Freak Reputation: 332. Thanks Given: 279 Thanks Received: 2890 (1034 Posts) Posts: 2,107 Threads: 155 Joined: Jul 2011 1 01-18-2020, 01:06 AM .…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Still not temp. Have fault traced with G/D. Replaced. Possible cause: 1 12-12-2015, 07:37 AM. cm871 low DOC temp won't reg to clear las...

The DPF system is a honeycomb filter, similar to a traditional catalytic converter, that captures and collects particulate soot. The 6.7 Cummins has had a DPF system since halfway through the 2007 model year. 2007.5-2012 models had a completely separate DPF system that sat behind the DOC system. In 2013+ models the DOC and …a. If the DOC inlet pressure starts out above 10 kPa (1.45 psi) and decreases during a parked regen, this indicates that the DPFs were plugged and the parked regen has cleared them. Go to step 8. b. If the DOC inlet pressure starts above the pressure specified below and stays high, the DOC is considered plugged. Go to step 9. Table 1. Emissions ...DOC inlet 500-600F DPF inlet starts to increase once regen starts. DPF outlet will increase after DPF inlet starts building temp and heat transfers through DPF. DPF outlet may peak slightly above inlet temp but should down below the inlet temp. …

A) A forced regen will take approximately 40 minutes. It will cycle through 6 stages during this 40 minute period. If the Regen cycle takes longer than this, something else is still wrong. b) During a forced regen cycle, The DOC will get to about 550F, and the doser will activate, first, usually in short intervals, then come on solid.Throttle Valve Actual NOT USED DURING A PARKED REGEN Fuel Comp Pressure 85 ... DOC Inlet Temp 700 – 950 ° F DOC Outlet Temp 1050 – 1150° F DPF Inlet Pressure 0.5 psi – 1.0 psi DPF Outlet Pressure 0.01 psi to 0.9 psi Doser Injection Status gradual increase from 5% to 45% • DOC inlet temp must be at 525° F or higher toNOTE: Normal DOC pressure is less than 10 kPa (1.5 psi) for a 1-Box™ emissions package and 13 kPa (1.9 psi) for a Two-Box option. 38. Using DiagnosticLink, monitor DOC inlet pressure while performing a parked regeneration. Refer to section "Performing a Parked Regeneration Using DiagnosticLink® Standard". Does the DOC inlet pressure start ...

kans logo Start looking at it, doc temps run up to 700 degrees within the first 5 minutes but I never see any pressure kick up from the Hydrocarbon doser. By 10 minute mark all temperatures holding steady around the 400-500 mark. Checked intake/exhaust leaks, intake throttle valve, egr valve, ensure all items are were they should be during the regen process.9. Start the engine and run a Parked Regen. Monitor DOC inlet pressure and engine speed during the regen. Compare your DOC inlet pressure reading to the screen shots and descriptions below in (a and b) to determine what step to go to next. a. If the DOC inlet pressure starts out high above 10 kPa (1.45 psi) and decreases during the parked regen ... bluechew girl admindfulness community 1 NUMBER: 2 ATS 07 S.M. REF.: Listed in Table 1 ENGINE: ATS DATE: April 2007 SUBJECT: UPDATES TO AFTERTREATMENT SYSTEM TROUBLESHOOTING PUBLICATION: 7SE63 The Aftertreatment System Technician's Guide has been revised. MANUAL REFERENCE Section 6.1, Mechanical Troubleshooting 9.1, SPN 3242/FMI , …EGT stands for Exhaust Gas Temperature. The EGT sensor is responsible for reading the temperatures of the aftertreatment system components such as inlet DOC, ... water well draw I have been working on this bus on and off for several months. It is trying to actively regen around every 2 hours. ISL9. CM2250. engine serial# *****. ECM code CB90010.41. Here are the specs I've gotten while a driving regen is going. DOC Intake Temp - 946.1 f. DPF Intake Temp - 1081.6 f. drinking age in kansascvs vaccine phone numberdavid jaynes Diesel Oxidation Catalyst: The DOC assists in elevating temperatures into the DPF to initiate the regeneration process. Fuel is injected into the exhaust by the Hydrocarbon (HC) fuel dosing system. The injected fuel is oxidized in the DOC, which raises the temperatures above passive mode operating temperatures. finance degree career paths Right away I noticed that the DOC inlet temperature reading was at 662 F (default max value as I found out) @ 1.7V, yet the outlet temperature was 419 F @ 1V . These thermo-couples run on 5V and generally have a much larger spread between temperature/voltage correlation. Now it was time to let the data talk.During a parked regen on a DD15, the SCR Inlet NOx sensor should be around 200-300ppm. DD13 SCR Inlet NOx sensor is slightly higher around 400-500ppm. The SCR Outlet NOx should be somewhere in the neighborhood of 5-25ppm for all DD Platforms. The other true method in testing the NOx sensors is to perform a regular parked regen, then perform ... witchia stateicbm silo locationsmusician in classical period 2022年2月16日 ... An engine oil consumption problem will be hard on a DPF. As Otto explained, the additives in engine oil cannot be oxidized away during a regen, ...May 4, 2021 · Hey Nick, I got a 2014 KW T800 with a paccar mx13. Got some fuel dosing regen issues.VIN: *****Unit will get up to 500 degrees at DOC inlet during regen and begin to dose fuel. DOC outlet … read more